CABLE TRAVELLER-COMMAND LIFT LEVEL
General Characteristics
In the flat cable, all drivers grouped in cells and sets of drivers are located in parallel, are covered by a PVC very flexible.
This design has the advantages of functional and technical, for example, require much less space in the elevator shaft, because of its smaller bending radius.
There is the possibility of torsion in the bend of the cable.
Have a long service life free of damage (if they are installed correctly).
Based on the specifications according to Standards: NM 280 Class 5 – IEC No. 60227-6 71F; UNE-en-50214.
Identification
The drivers are grouped into cells, and numbered consecutively.
Insulated PVC flexible, anti-flame and sheath outer color black.
The sheath outer wears printed on the same brand COELPLA, section and quantity of conductor, voltage, country of origin, and feet marked in a sequential way.
Electrical characteristics
Rated voltage: 0.75 – 1.00 mm2: 300 / 500 V
Mechanical Characteristics
Length-free hanging: max. 45 m
Height travel: max. 80 m
Speed of travel: up to 5 m/s
Bend diameter: 250 to 350 mm
Uses
Cables for lifts interiors and panoramic views
Conditioning
In coils.

